A mutually inductive measuring transducer of transverse displacements of a rectilinear conductor

Dettagli Bibliografici
Parent link:Russian Journal of Nondestructive Testing
Vol. 46, iss. 6.— 2010.— [P. 424-430]
Autore principale: Goldstein (Goldshtein) A. E. Aleksandr Efremovich
Altri autori: Fedorov E. M. Evgeniy Mihailovich
Riassunto:Title screen
The design of a mutually inductive measuring transducer is proposed. The main field of its use is measurements of the eccentricity of the current-conducting lead of an electrical cable relative to its insulating coating. An analytical expression for determining the transformation function is obtained. The optimal design parameters of the transducer are determined.
Режим доступа: по договору с организацией-держателем ресурса
Pubblicazione: 2010
Soggetti:
Accesso online:http://link.springer.com/article/10.1134/S1061830910060069
Natura: Elettronico Capitolo di libro
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=637775
Descrizione
Riassunto:Title screen
The design of a mutually inductive measuring transducer is proposed. The main field of its use is measurements of the eccentricity of the current-conducting lead of an electrical cable relative to its insulating coating. An analytical expression for determining the transformation function is obtained. The optimal design parameters of the transducer are determined.