| Shrnutí: | Title screen The design, main design formulas, and test results of a small-size differential high-voltage divider are presented. The conditions determining correctness of using the divider for measuring nanosecond high-voltage signals are obtained. It is shown that the differential voltage divider has some limitations in low- and high-frequency regions. Experiments have been performed on a TэY-500 pulsed electron accelerator with the following characteristics: the accelerating voltage is 350–450 kV, the base pulse duration is 100 ns, the rise time is <5 ns, and the complete pulse electron energy is up to 250 J. The pulse repetition rate is 1–3 pulses/s. To restore the shape of the measured voltage, it is necessary that the output signal from the voltage divider be integrated. The measurement error does not exceed ±10%. Режим доступа: по договору с организацией-держателем ресурса |
| Jazyk: | angličtina |
| Vydáno: |
2011
|
| Témata: | |
| On-line přístup: | http://dx.doi.org/10.1134/S0020441211020175 |
| Médium: | Elektronický zdroj Kapitola |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=637506 |
MARC
| LEADER | 00000nla0a2200000 4500 | ||
|---|---|---|---|
| 001 | 637506 | ||
| 005 | 20250422091256.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\1658 | ||
| 090 | |a 637506 | ||
| 100 | |a 20140923d2011 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a US | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a A differential high-voltage divider |f Yu. I. Isakova, A. I. Pushkarev, G. E. Kholodnaya | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 320 | |a [References: p. 186 (8 tit.)] | ||
| 330 | |a The design, main design formulas, and test results of a small-size differential high-voltage divider are presented. The conditions determining correctness of using the divider for measuring nanosecond high-voltage signals are obtained. It is shown that the differential voltage divider has some limitations in low- and high-frequency regions. Experiments have been performed on a TэY-500 pulsed electron accelerator with the following characteristics: the accelerating voltage is 350–450 kV, the base pulse duration is 100 ns, the rise time is <5 ns, and the complete pulse electron energy is up to 250 J. The pulse repetition rate is 1–3 pulses/s. To restore the shape of the measured voltage, it is necessary that the output signal from the voltage divider be integrated. The measurement error does not exceed ±10%. | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Instruments and Experimental Techniques |d 2000- | ||
| 463 | |t Vol. 54, iss. 2 |v [P. 183-186] |d 2011 | ||
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a высоковольтное напряжение | |
| 700 | 1 | |a Isakova |b Yu. I. |c physicist |c Associate Professor of Tomsk Polytechnic University, Candidate of Technical Sciences |f 1988- |g Yulia Ivanovna |3 (RuTPU)RU\TPU\pers\32700 |9 16586 | |
| 701 | 1 | |a Pushkarev |b A. I. |c physicist |c Professor of Tomsk Polytechnic University, Doctor of physical and mathematical sciences, Senior researcher |f 1954- |g Aleksandr Ivanovich |3 (RuTPU)RU\TPU\pers\32701 |9 16587 | |