Massive cryogenic particle detectors with low energy threshold; Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment; Vol. 466, iss. 3
| Parent link: | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment: Scientific Journal Vol. 466, iss. 3.— 2002.— [P. 499-508] |
|---|---|
| Other Authors: | , , , , , , , , , , , , |
| Summary: | Title screen We have developed massive cryogenic particle detectors to be used in the CRESST dark matter search. Each detector is made of a sapphire crystal and a tungsten superconducting phase transition thermometer. In this paper, we report on the results obtained with four 262 g detectors, which show energy thresholds as low as 350 e V and good energy resolution at low energies. The shape of the experimental pulses, the linearity of the detector response and the energy dependence of the resolution are discussed Режим доступа: по договору с организацией-держателем ресурса |
| Language: | English |
| Published: |
2002
|
| Subjects: | |
| Online Access: | http://www.sciencedirect.com/science/article/pii/S0168900201008014 http://elibrary.ru/item.asp?id=14121138 |
| Format: | Electronic Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=637180 |
MARC
| LEADER | 00000nla0a2200000 4500 | ||
|---|---|---|---|
| 001 | 637180 | ||
| 005 | 20250415164705.0 | ||
| 035 | |a (RuTPU)RU\TPU\network\1277 | ||
| 035 | |a RU\TPU\network\1261 | ||
| 090 | |a 637180 | ||
| 100 | |a 20140602d2001 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a NL | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Massive cryogenic particle detectors with low energy threshold |f M. Sisti [et al.] | |
| 203 | |a Text |c electronic | ||
| 300 | |a Title screen | ||
| 330 | |a We have developed massive cryogenic particle detectors to be used in the CRESST dark matter search. Each detector is made of a sapphire crystal and a tungsten superconducting phase transition thermometer. In this paper, we report on the results obtained with four 262 g detectors, which show energy thresholds as low as 350 e V and good energy resolution at low energies. The shape of the experimental pulses, the linearity of the detector response and the energy dependence of the resolution are discussed | ||
| 333 | |a Режим доступа: по договору с организацией-держателем ресурса | ||
| 461 | |t Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |o Scientific Journal | ||
| 463 | |t Vol. 466, iss. 3 |v [P. 499-508] |d 2002 | ||
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a электронный ресурс | |
| 701 | 1 | |a Sisti |b M. | |
| 701 | 1 | |a Meier |b O. | |
| 701 | 1 | |a Buhler |b M. | |
| 701 | 1 | |a Cooper |b S. | |
| 701 | 1 | |a Jorgens |b V. | |
| 701 | 1 | |a Loidl |b M. | |
| 701 | 1 | |a Nagel |b U. | |
| 701 | 1 | |a Probst |b F. | |
| 701 | 1 | |a Seidel |b W. | |
| 701 | 1 | |a Stolovits |b A. | |
| 701 | 1 | |a Stodolsky |b L. | |
| 701 | 1 | |a Uchaykin |b S. V. |c specialist in the field of non-destructive testing |c Engineer of Tomsk Polytechnic University, Doctor of physical and mathematical sciences |f 1963- |g Sergey Victorovich |3 (RuTPU)RU\TPU\pers\32279 | |
| 701 | 1 | |a Zerle |b L. | |
| 801 | 2 | |a RU |b 63413507 |c 20160512 |g RCR | |
| 850 | |a 63413507 | ||
| 856 | 4 | |u http://www.sciencedirect.com/science/article/pii/S0168900201008014 | |
| 856 | 4 | |u http://elibrary.ru/item.asp?id=14121138 | |
| 942 | |c CF | ||