High detection sensitivity achieved with cryogenic detectors in combination with matrix-assisted laser desorption / ionisation time-of-flight mass spectrometry (MALDI-TOF MS)
| Parent link: | European Journal of Mass Spectrometry: Scientific Journal.— , 1995- Vol. 10, iss. 4.— 2004.— [P. 469-476] |
|---|---|
| Altres autors: | Christ P., Rutzinger S., Koy C., Seidel W., Uchaykin S. V. Sergey Victorovich, Glocker M. O., Probst F. |
| Sumari: | Title screen Cryogenic detectors directly measure the impact energy of any impinging particle independent of its velocity. Thus a very high, mass-independent, detection efficiency is expected from their application in TOF-MS. The cryogenic detector applied here is based on a superconducting phase-transition thermometer and was implemented in a dual reflector time-of-flight mass spectrometer (N-geometry). A dilution series using standard sample preparation procedures shows that the detection limit for insulin (Mr: 5,734) can be decreased by several orders of magnitude, down to 0.5 amol on the MALDI target. Detection limits for rhM-CSF ß (Mr: 49,032) and for polyclonal IgG (Mr: ca. 150,000) in the high femtomole and low picomole range, respectively, were established |
| Idioma: | anglès |
| Publicat: |
2004
|
| Matèries: | |
| Accés en línia: | http://www.impublications.com/content/abstract?code=E10_0469 https://publications.mpp.mpg.de/?action=search&mpi=MPP-2003-141 |
| Format: | Electrònic Capítol de llibre |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=637165 |
Ítems similars
Quasiparticle diffusion over several mm in cryogenic detectors
Publicat: (2001)
Publicat: (2001)
Fast cryodetector and SQUID read-out for mass spectrometry
Publicat: (2002)
Publicat: (2002)
Developing of a fast cryodetector read-out for mass spectrometry
per: Uchaykin S. V. Sergey Victorovich
Publicat: (2001)
per: Uchaykin S. V. Sergey Victorovich
Publicat: (2001)
Time-of-Flight measurements with a detector using a liquid Cherenkov radiator-prototype of a possible TOF detector for the Super-FRS at FAIR
Publicat: (2019)
Publicat: (2019)
Application of cryogenic detectors in time-of-flight mass spectrometry of large biomolecules
Publicat: (2005)
Publicat: (2005)
Application of cryogenic detectors in time-of-flight mass spectrometry of large biomolecules
Publicat: (2005)
Publicat: (2005)
Cryogenic dispersion of molybdenite as a method to enhance activity of molybdenite-based bulky catalysts
Publicat: (2024)
Publicat: (2024)
Modeling of Onboard Cable at Cryogenic Temperatures and under Vacuum Conditions
Publicat: (2025)
Publicat: (2025)
Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam
Publicat: (2018)
Publicat: (2018)
Influence of Conditions of Cryogenic Molybdenite Grinding on the Activity of Bulk Sulfide Hydrotreating Catalysts
Publicat: (2020)
Publicat: (2020)
The concept of multi-channel ionizing radiation beam detector
Publicat: (2024)
Publicat: (2024)
Simulation study of the response of a highly sensitive silver-activation detector for neutron detection using MCNP code
per: Shehada A. Abdullah
Publicat: (2021)
per: Shehada A. Abdullah
Publicat: (2021)
Improvement of a Terahertz Detector Performance Using the Terajet Effect in a Mesoscale Dielectric Cube: Proof of Concept
Publicat: (2020)
Publicat: (2020)
SELDI-TOF Mass Spectrometry Methods and Protocols /
Publicat: (2012)
Publicat: (2012)
A design for a magnetic-wheeled flaw detector platform
per: Terentyev E. V. Evgeny Vladislavovich
Publicat: (2021)
per: Terentyev E. V. Evgeny Vladislavovich
Publicat: (2021)
Weld Defects Automatic Visual Recognition by Combined Application of Canny Edge Detector and Interval Fusion with Preference Aggregation
per: Muravyov (Murav’ev) S. V. Sergey Vasilyevich
Publicat: (2022)
per: Muravyov (Murav’ev) S. V. Sergey Vasilyevich
Publicat: (2022)
Исследование объемного упрочнения породоразрушающих элементов шарошечного долота посредством криогенной обработки
per: Нескоромных В. В. Вячеслав Васильевич
Publicat: (2025)
per: Нескоромных В. В. Вячеслав Васильевич
Publicat: (2025)
Algorithm for Optimizing the Parameters of Sandwich X-ray Detectors
per: Udod V. A. Viktor Anatolievich
Publicat: (2023)
per: Udod V. A. Viktor Anatolievich
Publicat: (2023)
Detector for coherent synchrotron radiation measurements from separate electron bunches in a millimeter wavelength region
Publicat: (2009)
Publicat: (2009)
Reconstructing Signals of Scintillation Detectors
Publicat: (2022)
Publicat: (2022)
Optimization of the LaBr3 detector model using differential evolution algorithms
Publicat: (2025)
Publicat: (2025)
Precision measurement of the structure of the CMS inner tracking system using nuclear interactions
Publicat: (2018)
Publicat: (2018)
Performance of missing transverse momentum reconstruction in proton-proton collisions at √s = 13 TeV using the CMS detector
Publicat: (2019)
Publicat: (2019)
Overview of the CMS beam loss monitoring system (BCML) and diamond detectors surface modification
per: Okhotnikov V. V. Vitaly Vladimirovich
Publicat: (2018)
per: Okhotnikov V. V. Vitaly Vladimirovich
Publicat: (2018)
The formation of amplitude spectra in X-ray pixel detectors made of gallium arsenide
per: Ayzenshtat G. I.
Publicat: (2017)
per: Ayzenshtat G. I.
Publicat: (2017)
Materials and techniques for hydrogen separation from methane-containing gas mixtures
Publicat: (2023)
Publicat: (2023)
Digital X-Ray Apparatus Based on the Scanning R-Ray Gas-Discharge Detector for Studying of Interior Structure of Biological Objects
Publicat: (2014)
Publicat: (2014)
Performance of the CMS muon trigger system in proton-proton collisions at √ 𝒔 = 13 TeV
Publicat: (2021)
Publicat: (2021)
Микробиологические лабораторные реакции учебное пособие для студентов медицинских вузов
per: Кузнецов О. Ю.
Publicat: (Иваново, Ивановский ГМУ, 2019)
per: Кузнецов О. Ю.
Publicat: (Иваново, Ивановский ГМУ, 2019)
Estimation of Radiation Doses in X-Ray Visualization of Biological Objects
Publicat: (2014)
Publicat: (2014)
MCNP Simulations for Silver-Plastic Scintillator Detector for Mono-Energy Neutrons 2.5 and 14 MeV
Publicat: (2021)
Publicat: (2021)
Cryogenic Detectors in Protein Analysis
Publicat: (2003)
Publicat: (2003)
Improvement of an infrared pyroelectric detector performances in thz range using the terajet effect
Publicat: (2021)
Publicat: (2021)
Characterizing the coaxial HPGe detector using Monte Carlo simulations and evolutionary algorithms
Publicat: (2021)
Publicat: (2021)
Способы подачи смазывающе-охлаждающих жидкостей при обработке титановых сплавов
per: Ласуков А. А. Александр Александрович
Publicat: (2023)
per: Ласуков А. А. Александр Александрович
Publicat: (2023)
Influence of Compartment Fire Behavior at Ignition and Combustion Development Stages on the Operation of Fire Detectors
Publicat: (2022)
Publicat: (2022)
The very forward CASTOR calorimeter of the CMS experiment
Publicat: (2021)
Publicat: (2021)
Performance of the reconstruction and identification of high-momentum muons in proton-proton collisions at √s = 13 TeV
Publicat: (2020)
Publicat: (2020)
Mathematical Models of Radiation Transparency of Test Objects When Using Sandwich X-Ray Radiation Detectors
per: Udod V. A. Viktor Anatolievich
Publicat: (2020)
per: Udod V. A. Viktor Anatolievich
Publicat: (2020)
Performance of reconstruction and identification of τ leptons decaying to hadrons and vτ in pp collisions at √s=13 TeV
Publicat: (2018)
Publicat: (2018)
Ítems similars
-
Quasiparticle diffusion over several mm in cryogenic detectors
Publicat: (2001) -
Fast cryodetector and SQUID read-out for mass spectrometry
Publicat: (2002) -
Developing of a fast cryodetector read-out for mass spectrometry
per: Uchaykin S. V. Sergey Victorovich
Publicat: (2001) -
Time-of-Flight measurements with a detector using a liquid Cherenkov radiator-prototype of a possible TOF detector for the Super-FRS at FAIR
Publicat: (2019) -
Application of cryogenic detectors in time-of-flight mass spectrometry of large biomolecules
Publicat: (2005)