Statistical evaluation of thermographic NDT performance applied to CFRP; Thermosense XVIII: An International Conference on Thermal Sensing and Imaging, Orlando, April 08, 1996

Библиографические подробности
Источник:Thermosense XVIII: An International Conference on Thermal Sensing and Imaging, Orlando, April 08, 1996.— 1996.— [P. 174-177]
Главный автор: Vavilov V. P. Vladimir Platonovich
Другие авторы: Bison P. G. Paolo G., Grinzato E. G. Ermanno G.
Примечания:Title screen
This paper contains inspection results for a carbon epoxy plastic reference specimen with TeflonTM inserts. A long-pulse heating technique and AGEMA-900 IR imager have been used. Results are presented as a set of twenty-two images including a source image, normalized image, timegram, depthgram, tomogram presented as B&W and color hard-copies, as well as live images on a color monitor. This set of data has been exhibited to operators (experts or not) together with the set of rules for detecting defects. Obtained data are processed statistically and compared with true defect locations. The Tanimoto criterion is used for data comparison. Recommendations on the best image processing technique, as well as on the best form of data presentation, are given
Режим доступа: по договору с организацией-держателем ресурса
Язык:английский
Опубликовано: 1996
Предметы:
Online-ссылка:http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1019381
Формат: Электронный ресурс Статья
Запись в KOHA:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=637010

MARC

LEADER 00000naa0a2200000 4500
001 637010
005 20250920105056.0
035 |a (RuTPU)RU\TPU\network\1078 
090 |a 637010 
100 |a 20140424d1996 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drnn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Statistical evaluation of thermographic NDT performance applied to CFRP  |f V. P. Vavilov, P. G. Bison, E. G. Grinzato 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [Ref.: p. 176 (10 tit.)] 
330 |a This paper contains inspection results for a carbon epoxy plastic reference specimen with TeflonTM inserts. A long-pulse heating technique and AGEMA-900 IR imager have been used. Results are presented as a set of twenty-two images including a source image, normalized image, timegram, depthgram, tomogram presented as B&W and color hard-copies, as well as live images on a color monitor. This set of data has been exhibited to operators (experts or not) together with the set of rules for detecting defects. Obtained data are processed statistically and compared with true defect locations. The Tanimoto criterion is used for data comparison. Recommendations on the best image processing technique, as well as on the best form of data presentation, are given 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
463 1 |t Thermosense XVIII: An International Conference on Thermal Sensing and Imaging, Orlando, April 08, 1996  |o Proc. SPIE 2766  |v [P. 174-177]  |d 1996 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
700 1 |a Vavilov  |b V. P.  |c Specialist in the field of dosimetry and methodology of nondestructive testing (NDT)  |c Doctor of technical sciences (DSc), Professor of Tomsk Polytechnic University (TPU)  |f 1949-  |g Vladimir Platonovich  |3 (RuTPU)RU\TPU\pers\32161  |9 16163 
701 1 |a Bison  |b P. G.  |g Paolo G. 
701 1 |a Grinzato  |b E. G.  |g Ermanno G. 
801 2 |a RU  |b 63413507  |c 20140424  |g RCR 
856 4 |u http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1019381 
942 |c BK