IR thermographic inspection of filament wound CFRP shell samples; Thermosense XXIX, Orlando, April 09-12, 2007

Dades bibliogràfiques
Parent link:Thermosense XXIX, Orlando, April 09-12, 2007.— 2007.— [12 p.]
Altres autors: Lahiri J. Jhumur, Srinivas K., Siddiqui A. O. Ahmad O., Vavilov V. P. Vladimir Platonovich
Sumari:Title screen
The paper describes theoretical and experimental results of the inspection of 5 mm- and 15 mm-thick filament wound CFRP shell samples containing Teflon inserts as defect surrogates. Heating was accomplished with a 30 kW tubular quartz lamp heater which provided up to 14 kW/m2 of absorbed power. Thermal properties of the samples were evaluated including the analysis of diffusivity anisotropy. Both one- and two-sided test procedures were comparatively investigated to illustrate difficulties which appeared in the inspection of thick composites
Режим доступа: по договору с организацией-держателем ресурса
Idioma:anglès
Publicat: 2007
Matèries:
Accés en línia:http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1301850
Format: MixedMaterials Electrònic Capítol de llibre
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=636989

MARC

LEADER 00000naa0a2200000 4500
001 636989
005 20250920103646.0
035 |a (RuTPU)RU\TPU\network\1057 
090 |a 636989 
100 |a 20140423d2007 k||y0rusy50 ba 
101 0 |a eng 
102 |a US 
135 |a drnn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a IR thermographic inspection of filament wound CFRP shell samples  |f J. Lahiri [et al.] 
203 |a Text  |c electronic 
300 |a Title screen 
320 |a [Ref.: (18 tit.)] 
330 |a The paper describes theoretical and experimental results of the inspection of 5 mm- and 15 mm-thick filament wound CFRP shell samples containing Teflon inserts as defect surrogates. Heating was accomplished with a 30 kW tubular quartz lamp heater which provided up to 14 kW/m2 of absorbed power. Thermal properties of the samples were evaluated including the analysis of diffusivity anisotropy. Both one- and two-sided test procedures were comparatively investigated to illustrate difficulties which appeared in the inspection of thick composites 
333 |a Режим доступа: по договору с организацией-держателем ресурса 
463 1 |t Thermosense XXIX, Orlando, April 09-12, 2007  |o Proc. SPIE 6541  |v [12 p.]  |d 2007 
610 1 |a электронный ресурс 
610 1 |a труды учёных ТПУ 
610 1 |a ИК-термография 
610 1 |a thermal testing 
610 1 |a тепловой неразрушающий контроль 
610 1 |a carbon fiber reinforced 
610 1 |a углепластики 
701 1 |a Lahiri  |b J.  |g Jhumur 
701 1 |a Srinivas  |b K. 
701 1 |a Siddiqui  |b A. O.  |g Ahmad O. 
701 1 |a Vavilov  |b V. P.  |c Specialist in the field of dosimetry and methodology of nondestructive testing (NDT)  |c Doctor of technical sciences (DSc), Professor of Tomsk Polytechnic University (TPU)  |f 1949-  |g Vladimir Platonovich  |3 (RuTPU)RU\TPU\pers\32161  |9 16163 
801 2 |a RU  |b 63413507  |c 20140423  |g RCR 
856 4 |u http://proceedings.spiedigitallibrary.org/proceeding.aspx?articleid=1301850 
942 |c CF