Решение проблемы томографического сканирования объектов детекторами малого размера; Перспективы развития фундаментальных наук; Т. 1 : Физика
| Источник: | Перспективы развития фундаментальных наук=Prospects of Fundamental Sciences Development: сборник научных трудов XIV Международной конференции студентов, аспирантов и молодых ученых, г. Томск, 25-28 апреля 2017 г./ Национальный исследовательский Томский политехнический университет (ТПУ) ; под ред. И. А. Курзиной, Г. А. Вороновой.— , 2017 Т. 1 : Физика.— 2017.— [С. 255-257] |
|---|---|
| Главный автор: | |
| Автор-организация: | |
| Другие авторы: | |
| Примечания: | Заглавие с экрана Standard X-Ray tomographic setups basically consist of 3 parts: radiation source, mechanics for mounting a sample and detector system. Each part of tomographic setup in one way or another contributes into the quality of reconstructed images. Detector system is responsible for data acquisition process. Development of detectors improves them in terms of resolution, acquisition speed, dark current etc. Such improvements increases costs for producing of detectors as well as their final price. Tomographic scanning of long objects requires using detectors of corresponding size. It makes tomographic setups expensive, because the price of detectors also increases with increasing of their size. Presented work proposes to solve this problem by shifting detector along the longest dimension of the sample and applying optimized filtered backprojection algorithm. |
| Язык: | русский |
| Опубликовано: |
2017
|
| Предметы: | |
| Online-ссылка: | http://earchive.tpu.ru/handle/11683/41462 |
| Формат: | MixedMaterials Электронный ресурс Статья |
| Запись в KOHA: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=622690 |
MARC
| LEADER | 00000naa2a2200000 4500 | ||
|---|---|---|---|
| 001 | 622690 | ||
| 005 | 20231101133226.0 | ||
| 035 | |a (RuTPU)RU\TPU\conf\21492 | ||
| 035 | |a RU\TPU\conf\21491 | ||
| 090 | |a 622690 | ||
| 100 | |a 20170704d2017 k y0rusy50 ca | ||
| 101 | 0 | |a rus |d eng | |
| 102 | |a RU | ||
| 105 | |a y z 100zy | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Решение проблемы томографического сканирования объектов детекторами малого размера |d Solution to the problem of tomographic scanning of objects by small area X-Ray detectors |f А. Х. Оздиев |g науч. рук. Ю. Ю. Крючков | |
| 203 | |a Текст |c электронный | ||
| 230 | |a 1 компьютерный файл (pdf; 580 Kb) | ||
| 300 | |a Заглавие с экрана | ||
| 320 | |a [Библиогр.: с. 257 (2 назв.)] | ||
| 330 | |a Standard X-Ray tomographic setups basically consist of 3 parts: radiation source, mechanics for mounting a sample and detector system. Each part of tomographic setup in one way or another contributes into the quality of reconstructed images. Detector system is responsible for data acquisition process. Development of detectors improves them in terms of resolution, acquisition speed, dark current etc. Such improvements increases costs for producing of detectors as well as their final price. Tomographic scanning of long objects requires using detectors of corresponding size. It makes tomographic setups expensive, because the price of detectors also increases with increasing of their size. Presented work proposes to solve this problem by shifting detector along the longest dimension of the sample and applying optimized filtered backprojection algorithm. | ||
| 461 | 1 | |0 (RuTPU)RU\TPU\conf\21388 |t Перспективы развития фундаментальных наук |l Prospects of Fundamental Sciences Development |o сборник научных трудов XIV Международной конференции студентов, аспирантов и молодых ученых, г. Томск, 25-28 апреля 2017 г. |o в 7 т. |f Национальный исследовательский Томский политехнический университет (ТПУ) ; под ред. И. А. Курзиной, Г. А. Вороновой |d 2017 | |
| 463 | 1 | |0 (RuTPU)RU\TPU\conf\21389 |t Т. 1 : Физика |v [С. 255-257] |d 2017 | |
| 510 | 1 | |a Solution to the problem of tomographic scanning of objects by small area X-Ray detectors |z eng | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a рентгеновские детекторы | |
| 610 | 1 | |a томографическое исследование | |
| 610 | 1 | |a сканирование | |
| 610 | 1 | |a излучение | |
| 610 | 1 | |a пучки | |
| 700 | 1 | |a Оздиев |b А. Х. |c физик |c инженер-проектировщик Томского политехнического университета |f 1990- |g Али Хосенович |2 stltpush |3 (RuTPU)RU\TPU\pers\34930 | |
| 702 | 1 | |a Крючков |b Ю. Ю. |c физик |c профессор Томского политехнического университета, доктор физико-математических наук |f 1945- |g Юрий Юрьевич |2 stltpush |4 727 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Физико-технический институт (ФТИ) |b Кафедра общей физики (ОФ) |h 136 |2 stltpush |3 (RuTPU)RU\TPU\col\18734 |
| 801 | 2 | |a RU |b 63413507 |c 20170718 |g RCR | |
| 856 | 4 | |u http://earchive.tpu.ru/handle/11683/41462 | |
| 942 | |c BK | ||