Уменьшение дозы облучения пациента при томографическом исследовании путём применения оптимизированного алгоритма обратного проецирования; Перспективы развития фундаментальных наук; Т. 1 : Физика
| Parent link: | Перспективы развития фундаментальных наук=Prospects of Fundamental Sciences Development: сборник научных трудов XIV Международной конференции студентов, аспирантов и молодых ученых, г. Томск, 25-28 апреля 2017 г./ Национальный исследовательский Томский политехнический университет (ТПУ) ; под ред. И. А. Курзиной, Г. А. Вороновой.— , 2017 Т. 1 : Физика.— 2017.— [С. 252-254] |
|---|---|
| Päätekijä: | |
| Yhteisötekijä: | |
| Muut tekijät: | |
| Yhteenveto: | Заглавие с экрана X-Ray tomography is one of widespread methods of medical diagnostics. Due to its opportunity to visualize inside structure of scanned object it allows to diagnose, for example, cancer cells. Modern medical tomographic setups have lots of advantages such as high resolution, which allows to visualize objects of very small size, high level of reproducibility, which allows to verify obtained results, simplicity of utilization etc. There is certain amount of improvements still can be applied. One of most significant challenges is reducing of radiation dose. Diagnostics of complex structures sometimes requires more time of measurements. That means that dose will increase with time. This work proposes optimized filtered backprojection algorithm as solution for the problem of radiation dose level. |
| Kieli: | venäjä |
| Julkaistu: |
2017
|
| Aiheet: | |
| Linkit: | http://earchive.tpu.ru/handle/11683/41461 |
| Aineistotyyppi: | Elektroninen Kirjan osa |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=622689 |
MARC
| LEADER | 00000naa2a2200000 4500 | ||
|---|---|---|---|
| 001 | 622689 | ||
| 005 | 20231101133226.0 | ||
| 035 | |a (RuTPU)RU\TPU\conf\21491 | ||
| 035 | |a RU\TPU\conf\21488 | ||
| 090 | |a 622689 | ||
| 100 | |a 20170704d2017 k y0rusy50 ca | ||
| 101 | 0 | |a rus |d eng | |
| 102 | |a RU | ||
| 105 | |a y z 100zy | ||
| 135 | |a drcn ---uucaa | ||
| 181 | 0 | |a i | |
| 182 | 0 | |a b | |
| 200 | 1 | |a Уменьшение дозы облучения пациента при томографическом исследовании путём применения оптимизированного алгоритма обратного проецирования |d Reduction of radiation dose by application of optimized filtered backprojection algorithm |f А. Х. Оздиев |g науч. рук. Ю. Ю. Крючков | |
| 203 | |a Текст |c электронный | ||
| 230 | |a 1 компьютерный файл (pdf; 501 Kb) | ||
| 300 | |a Заглавие с экрана | ||
| 320 | |a [Библиогр.: с. 254 (3 назв.)] | ||
| 330 | |a X-Ray tomography is one of widespread methods of medical diagnostics. Due to its opportunity to visualize inside structure of scanned object it allows to diagnose, for example, cancer cells. Modern medical tomographic setups have lots of advantages such as high resolution, which allows to visualize objects of very small size, high level of reproducibility, which allows to verify obtained results, simplicity of utilization etc. There is certain amount of improvements still can be applied. One of most significant challenges is reducing of radiation dose. Diagnostics of complex structures sometimes requires more time of measurements. That means that dose will increase with time. This work proposes optimized filtered backprojection algorithm as solution for the problem of radiation dose level. | ||
| 461 | 1 | |0 (RuTPU)RU\TPU\conf\21388 |t Перспективы развития фундаментальных наук |l Prospects of Fundamental Sciences Development |o сборник научных трудов XIV Международной конференции студентов, аспирантов и молодых ученых, г. Томск, 25-28 апреля 2017 г. |o в 7 т. |f Национальный исследовательский Томский политехнический университет (ТПУ) ; под ред. И. А. Курзиной, Г. А. Вороновой |d 2017 | |
| 463 | 1 | |0 (RuTPU)RU\TPU\conf\21389 |t Т. 1 : Физика |v [С. 252-254] |d 2017 | |
| 510 | 1 | |a Reduction of radiation dose by application of optimized filtered backprojection algorithm |z eng | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a излучение | |
| 610 | 1 | |a облучение | |
| 610 | 1 | |a томографическое исследование | |
| 610 | 1 | |a сканирование | |
| 610 | 1 | |a синограммы | |
| 700 | 1 | |a Оздиев |b А. Х. |c физик |c инженер-проектировщик Томского политехнического университета |f 1990- |g Али Хосенович |2 stltpush |3 (RuTPU)RU\TPU\pers\34930 | |
| 702 | 1 | |a Крючков |b Ю. Ю. |c физик |c профессор Томского политехнического университета, доктор физико-математических наук |f 1945- |g Юрий Юрьевич |2 stltpush |4 727 | |
| 712 | 0 | 2 | |a Национальный исследовательский Томский политехнический университет (ТПУ) |b Физико-технический институт (ФТИ) |b Кафедра общей физики (ОФ) |h 136 |2 stltpush |3 (RuTPU)RU\TPU\col\18734 |
| 801 | 2 | |a RU |b 63413507 |c 20170718 |g RCR | |
| 856 | 4 | |u http://earchive.tpu.ru/handle/11683/41461 | |
| 942 | |c BK | ||