Автоматизация установки для измерения параметров цифровых быстродействующих камер

Bibliographic Details
Parent link:Перспективы развития фундаментальных наук.— 2015.— [С. 1521-1523]
Main Author: Оздиев А. Х. Али Хосенович
Corporate Authors: Национальный исследовательский Томский политехнический университет (ТПУ) Физико-технический институт (ФТИ) Кафедра электроники и автоматики физических установок (№ 24) (ЭАФУ), Национальный исследовательский Томский политехнический университет (ТПУ) Физико-технический институт (ФТИ) Кафедра общей физики (ОФ)
Other Authors: Карпов Д. А. Дмитрий Андреевич (727), Ливенцов С. Н. Сергей Николаевич
Summary:Заглавие с экрана
Current X-ray radiation sources allow investigation of dynamic processes in such fields as life sciences, nanotechnology, medicine etc. Measurements of the processes rely strongly on the performance of the detector system. High-speed digital cameras are the main component of indirect X-ray detector system. These cameras have a set of parameters which affect resulting data quality significantly. There are two major camera technologies used in the indirect detector systems which are only different in sensor architecture, i.e. CCD and CMOS sensors. In the current work we are presenting Visible Light Setup (VLS) that was designed and assembled at the Institute of Photon Science and Synchrotron Radiation of Karlsruhe Institute of Technology. Assembled test bench allows characterization of camera parameters such as: sensor nonuniformities, defect pixels, linearity, noise, spectral sensitivity etc. The process of measurements is timeconsuming especially for users who are new to the method and the VLS setup. The performed work was aimed at the automation of the VLS setup, which provides significant decrease of measurement time, increases accuracy and reproducibility of the measurements and also improves simplicity of utilization.
Language:Russian
Published: 2015
Series:IT-технологии и электроника
Subjects:
Online Access:http://earchive.tpu.ru/handle/11683/19118
http://www.lib.tpu.ru/fulltext/c/2015/C21/494.pdf
Format: Electronic Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=613272
Description
Physical Description:1 файл(377 Кб)
Summary:Заглавие с экрана
Current X-ray radiation sources allow investigation of dynamic processes in such fields as life sciences, nanotechnology, medicine etc. Measurements of the processes rely strongly on the performance of the detector system. High-speed digital cameras are the main component of indirect X-ray detector system. These cameras have a set of parameters which affect resulting data quality significantly. There are two major camera technologies used in the indirect detector systems which are only different in sensor architecture, i.e. CCD and CMOS sensors. In the current work we are presenting Visible Light Setup (VLS) that was designed and assembled at the Institute of Photon Science and Synchrotron Radiation of Karlsruhe Institute of Technology. Assembled test bench allows characterization of camera parameters such as: sensor nonuniformities, defect pixels, linearity, noise, spectral sensitivity etc. The process of measurements is timeconsuming especially for users who are new to the method and the VLS setup. The performed work was aimed at the automation of the VLS setup, which provides significant decrease of measurement time, increases accuracy and reproducibility of the measurements and also improves simplicity of utilization.