Стенд для изучения электрохимической проницаемости водорода через металлические фольги; Перспективы развития фундаментальных наук
| Parent link: | Перспективы развития фундаментальных наук.— 2014.— [С. 247-249] |
|---|---|
| Glavni autor: | |
| Autor kompanije: | |
| Daljnji autori: | |
| Sažetak: | Заглавие с экрана This work describes the design, the basic components and principle of working the experimental Stand for Testing Electrochemical Permeation (STEP) of hydrogen through the metal foils. Diffusion coefficient and the time diffusing hydrogen was determined in titanium foils VT1-0 by electrochemical penetration. The impact of surface condition on the permeation time and the diffusion coefficient of hydrogen investigated. |
| Jezik: | ruski |
| Izdano: |
2014
|
| Serija: | Физика |
| Teme: | |
| Online pristup: | http://www.lib.tpu.ru/fulltext/c/2014/C21/078.pdf |
| Format: | Elektronički Poglavlje knjige |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=606879 |
| Opis fizičkog objekta: | 1 файл(519 Кб) |
|---|---|
| Sažetak: | Заглавие с экрана This work describes the design, the basic components and principle of working the experimental Stand for Testing Electrochemical Permeation (STEP) of hydrogen through the metal foils. Diffusion coefficient and the time diffusing hydrogen was determined in titanium foils VT1-0 by electrochemical penetration. The impact of surface condition on the permeation time and the diffusion coefficient of hydrogen investigated. |