Effect of the size of the scanning spot and the frequency characteristics of the photoreceiver on the sensitivity of active thermal testing; The Soviet journal of nondestructive testing; Vol. 20, iss. 4
| Parent link: | The Soviet journal of nondestructive testing.— , 1965- Vol. 20, iss. 4.— 1984.— P. 269-272 |
|---|---|
| Hoofdauteur: | |
| Andere auteurs: | , |
| Samenvatting: | The criterion for distinguishing defects is investigated as a function of the ratio of the dimensions of the scanning spot and of the defect, taking into account the frequency characteristics of pyroelectric and photovoltaic receivers. The optimum ratio of these quantities which ensures maximum sensitivity in active thermal monitoring is established. В фонде НТБ ТПУ отсутствует |
| Taal: | Engels |
| Gepubliceerd in: |
1984
|
| Onderwerpen: | |
| Formaat: | Hoofdstuk |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=601422 |
| Samenvatting: | The criterion for distinguishing defects is investigated as a function of the ratio of the dimensions of the scanning spot and of the defect, taking into account the frequency characteristics of pyroelectric and photovoltaic receivers. The optimum ratio of these quantities which ensures maximum sensitivity in active thermal monitoring is established. В фонде НТБ ТПУ отсутствует |
|---|