A method of coincidence and anti-coincidence circuit characteristics measurements
| Parent link: | Nuclear Instruments and Methods.— , 1972 Vol. 100, № 1.— 1972.— P. 73-75 |
|---|---|
| Other Authors: | , , , |
| Summary: | A method is described to measure automatically coincidence and anti-coincidence circuit characteristics by means of a time-toamplitude converter that allows to obtain resolution curves of circuits apart from time spread in the detectors, to choose easily the time resolution required in a particular experiment and estimate accidental coincidences and efficiency of a circuit obviating the need for any variable delay lines and monitors. В фонде НТБ ТПУ отсутствует |
| Published: |
1972
|
| Subjects: | |
| Format: | Book Chapter |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=597218 |
| Summary: | A method is described to measure automatically coincidence and anti-coincidence circuit characteristics by means of a time-toamplitude converter that allows to obtain resolution curves of circuits apart from time spread in the detectors, to choose easily the time resolution required in a particular experiment and estimate accidental coincidences and efficiency of a circuit obviating the need for any variable delay lines and monitors. В фонде НТБ ТПУ отсутствует |
|---|