Sumari:The introduction of pulses into the cable and the extraction of pulses from it were accomplished by means of pulse transformers based on ferrite cores built directly into the coaxial cable in such a way that the central conductor was used as the turn on the secondary or primary winding. This circuit was used to accomplish recirculation of a pulse 12 nsec long in a superconducting coaxial cable 100 m long with an inner conductor of Nb wire 0. 26 mm in diameter and an outer conductor consisting of a Pb sheath 2. 2 mm in diameter; the insulation consisted of Teflon. The wave impedance of the cable was 75 OMEGA . Oscillograms of pulses extracted from the cable after the first, third, seventh, and seventeenth passages through the cable corresponding to delay of the pulse by 0. 5, 1. 5, 3. 5, and 8. 5 mu sec, are shown
В фонде НТБ ТПУ отсутствует
Idioma:anglès
Publicat: 1975
Matèries:
Format: Capítol de llibre
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=595833

MARC

LEADER 00000naa0a2200000 4500
001 595833
005 20250313170626.0
035 |a (RuTPU)RU\TPU\tpu\17645 
035 |a RU\TPU\tpu\17630 
090 |a 595833 
100 |a 20100616d1975 k||y0rusy50 ba 
101 0 |a eng 
102 |a RU 
200 1 |a Recirculation of Nanosecond Pulses in a Superconducting Cable  |f A. N. Didenko [et al.] 
330 |a The introduction of pulses into the cable and the extraction of pulses from it were accomplished by means of pulse transformers based on ferrite cores built directly into the coaxial cable in such a way that the central conductor was used as the turn on the secondary or primary winding. This circuit was used to accomplish recirculation of a pulse 12 nsec long in a superconducting coaxial cable 100 m long with an inner conductor of Nb wire 0. 26 mm in diameter and an outer conductor consisting of a Pb sheath 2. 2 mm in diameter; the insulation consisted of Teflon. The wave impedance of the cable was 75 OMEGA . Oscillograms of pulses extracted from the cable after the first, third, seventh, and seventeenth passages through the cable corresponding to delay of the pulse by 0. 5, 1. 5, 3. 5, and 8. 5 mu sec, are shown 
333 |a В фонде НТБ ТПУ отсутствует 
461 |t Instruments and Experimental Techniques 
463 |t № 18 (5 pt 1)  |v P. 1460-1461  |d 1975 
610 1 |a труды учёных ТПУ 
701 1 |a Didenko  |b A. N.  |4 070 
701 1 |a Zelentsov  |b V. I.  |4 070 
701 1 |a Shiyan  |b V. P.  |4 070 
701 1 |a Yushkov  |b Y. G.  |c Russian scientist  |c Professor of Tomsk Polytechnic University  |f 1937-  |g Yuri Georgievich  |3 (RuTPU)RU\TPU\pers\25936  |4 070 
801 0 |a RU  |b 63413507  |c 20011210  |g PSBO 
801 2 |a RU  |b 63413507  |c 20120117  |g PSBO 
942 |c CR