Parametric X-ray radiation and texture of polycrystalline foils; Resource-Efficient Technologies; No 2

Bibliografiske detaljer
Parent link:Resource-Efficient Technologies: electronic scientific journal/ National Research Tomsk Polytechnic University (TPU).— , 2015-.— 2405-6537
No 2.— 2018.— [P. 12-15]
Andre forfattere: Alexeyev V. I., Eliseyev A. N., Irribarra E., Kishin I. A., Kubankin A. S., Nazhmudinov R. M.
Summary:Title screen
The texture of polycrystalline foils of tungsten and nickel was studied using Parametric X-ray Radiation (PXR) generated by7 MeV electrons. The PXR rocking curves from crystallographic planes (200) for tungsten and (220) for nickel were obtained.A comparison with similar measurements obtained using diffraction of broadband X-rays is presented. The comparison showed agood compliance of the results concerning the form of the rocking curves and the position of the maximums. However, a systema-tic discrepancy in the value of the Full Width Half Maximum was observed.
Sprog:engelsk
Udgivet: 2018
Fag:
Online adgang:http://www.ojs.tpu.ru/index.php/res-eff/article/view/190/167
http://earchive.tpu.ru/handle/11683/51441
https://doi.org/10.18799/24056537/2018/2/190
Format: MixedMaterials Electronisk Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=580791

MARC

LEADER 00000naa2a2200000 4500
001 580791
005 20231101130630.0
035 |a (RuTPU)RU\TPU\prd\280650 
035 |a RU\TPU\prd\280649 
090 |a 580791 
100 |a 20181019a2018 k y0rusy50 ba 
101 0 |a eng 
102 |a RU 
135 |a drcn ---uucaa 
181 0 |a i  
182 0 |a b 
200 1 |a Parametric X-ray radiation and texture of polycrystalline foils  |f V. I. Alexeyev, A. N. Eliseyev, E. Irribarra [et al.] 
203 |a Text  |c electronic 
215 |a 1 файл(3525 Кб) 
230 |a Электронные текстовые данные (1 файл: 3525 Кб) 
300 |a Title screen 
320 |a [References: p. 15 (20 tit.)] 
330 |a The texture of polycrystalline foils of tungsten and nickel was studied using Parametric X-ray Radiation (PXR) generated by7 MeV electrons. The PXR rocking curves from crystallographic planes (200) for tungsten and (220) for nickel were obtained.A comparison with similar measurements obtained using diffraction of broadband X-rays is presented. The comparison showed agood compliance of the results concerning the form of the rocking curves and the position of the maximums. However, a systema-tic discrepancy in the value of the Full Width Half Maximum was observed. 
461 1 |0 (RuTPU)RU\TPU\prd\247369  |x 2405-6537  |t Resource-Efficient Technologies  |o electronic scientific journal  |f National Research Tomsk Polytechnic University (TPU)  |d 2015- 
463 1 |0 (RuTPU)RU\TPU\prd\280647  |t No 2  |v [P. 12-15]  |d 2018 
610 1 |a труды учёных ТПУ 
610 1 |a электронный ресурс 
610 1 |a X-ray radiation 
610 1 |a parametric X-rays 
610 1 |a curves 
610 1 |a bremsstrahlung 
610 1 |a рентгеновское излучение 
610 1 |a фольга 
610 1 |a текстура 
610 1 |a поляризация 
701 1 |a Alexeyev  |b V. I. 
701 1 |a Eliseyev  |b A. N. 
701 1 |a Irribarra  |b E. 
701 1 |a Kishin  |b I. A. 
701 1 |a Kubankin  |b A. S. 
701 1 |a Nazhmudinov  |b R. M. 
801 1 |a RU  |b 63413507  |c 20090623  |g PSBO 
801 2 |a RU  |b 63413507  |c 20220418  |g PSBO 
856 4 |u http://www.ojs.tpu.ru/index.php/res-eff/article/view/190/167 
856 4 |u http://earchive.tpu.ru/handle/11683/51441 
856 4 |u https://doi.org/10.18799/24056537/2018/2/190 
942 |c BK