Analysis of X-ray whispering gallery waves propagating along liquid meniscuses

التفاصيل البيبلوغرافية
Parent link:Resource-Efficient Technologies: electronic scientific journal/ National Research Tomsk Polytechnic University (TPU).— , 2015-.— 2405-6537
No 1.— 2018.— [P. 47-54]
مؤلفون آخرون: Goray L. I., Asadchikov V. E, Roshchin B. S, Volkov Y. O, Tikhonov A. M
الملخص:Title screen
X-ray diffraction and fluorescence of whispering galleries (WGs) which propagate along meniscuses of deionized water or silicahydrosols enriched by CsOH have been analyzed for the first time. The measurements have been performed using the diffractometer with a moving tube-detector system. The X-ray beam rotation angle reached a maximum value of 4° on a silica hydrosol sample. The WG mode propagating near the surface of a concave meniscus as well as the fluorescence intensity have been found from a solution of the respective Helmholtz equations. For analysis of intensities of the X-ray scattering and fluorescence we have used a two-layer model of the liquid with the upper non-uniform corrugated layer in which the concentration of levitating Cs+ ions near the surface has a maximum derived from the experiment in the hydrosol depth of ~ 15 nm for SiO2particle sizes of ~ 5...7 nm. In order to determine the fluorescence intensity we have used the approach based on a method of fundamental parameters using the reciprocity theorem.
منشور في: 2018
الموضوعات:
الوصول للمادة أونلاين:http://www.ojs.tpu.ru/index.php/res-eff/article/view/182/156
http://earchive.tpu.ru/handle/11683/51419
https://doi.org/10.18799/24056537/2018/1/182
التنسيق: الكتروني فصل الكتاب
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=580787
الوصف
وصف مادي:1 файл(637 Кб)
الملخص:Title screen
X-ray diffraction and fluorescence of whispering galleries (WGs) which propagate along meniscuses of deionized water or silicahydrosols enriched by CsOH have been analyzed for the first time. The measurements have been performed using the diffractometer with a moving tube-detector system. The X-ray beam rotation angle reached a maximum value of 4° on a silica hydrosol sample. The WG mode propagating near the surface of a concave meniscus as well as the fluorescence intensity have been found from a solution of the respective Helmholtz equations. For analysis of intensities of the X-ray scattering and fluorescence we have used a two-layer model of the liquid with the upper non-uniform corrugated layer in which the concentration of levitating Cs+ ions near the surface has a maximum derived from the experiment in the hydrosol depth of ~ 15 nm for SiO2particle sizes of ~ 5...7 nm. In order to determine the fluorescence intensity we have used the approach based on a method of fundamental parameters using the reciprocity theorem.
DOI:10.18799/24056537/2018/1/182