Influence of geometric parameters on the quality of VMAT plans in inverse planning; AIP Conference Proceedings; Vol. 2820, iss. 1 : International Conference on Scientific Research and Innovation 2022 (ICSRI 2022)
| Parent link: | AIP Conference Proceedings Vol. 2820, iss. 1 : International Conference on Scientific Research and Innovation 2022 (ICSRI 2022).— 2023.— 020009, 9 p. |
|---|---|
| Autres auteurs: | , , , |
| Résumé: | Title screen Modern radiotherapy modalities allow irradiation of the tumor to high dose values and irradiation of organs at risk to low dose values at the same time. This paper studies geometrical radiation treatment plan parameters made in the Monaco system for Elekta Synergy linear accelerator. This study aims to select the optimal geometric characteristics of the plan with different target volume types. In the framework of the study, 12 dosimetric plans were created for each case. For the first case, anatomical data of a patient with prostate cancer was chosen in the mode of high-dose hypofractionated radiotherapy (5 fractions of 7.25 Gy). For the second case, the dosimetric treatment plans were prepared for the patient’s anatomical data with a complex shape of the target volume, base of tongue cancer, in the simultaneous integrated boost VMAT mode (25 fractions of 2.0 and 2.4 Gy) AM_Agreement |
| Langue: | anglais |
| Publié: |
2023
|
| Sujets: | |
| Accès en ligne: | https://doi.org/10.1063/5.0150411 |
| Format: | Électronique Chapitre de livre |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=379325 |
MARC
| LEADER | 00000naa2a2200000 4500 | ||
|---|---|---|---|
| 001 | 379325 | ||
| 005 | 20250507162812.0 | ||
| 035 | |a (RuTPU)RU\TPU\retro\36792 | ||
| 035 | |a RU\TPU\network\40422 | ||
| 090 | |a 379325 | ||
| 100 | |a 20230911d2023 k||y0rusy50 ba | ||
| 101 | 0 | |a eng | |
| 102 | |a US | ||
| 135 | |a drgn ---uucaa | ||
| 181 | 0 | |a i |b e | |
| 182 | 0 | |a b | |
| 183 | 0 | |a cr |2 RDAcarrier | |
| 200 | 1 | |a Influence of geometric parameters on the quality of VMAT plans in inverse planning |d Влияние геометрических параметров на качество VMAT планов облучения при инверсном планировании объемно-модулированной лучевой терапии |f E. S. Sukhikh, L. G. Sukhikh, A. V. Vertinsky, O. M. Stakhova | |
| 203 | |a Текст |c электронный |b визуальный | ||
| 283 | |a online_resource |2 RDAcarrier | ||
| 300 | |a Title screen | ||
| 320 | |a References: 24 tit | ||
| 330 | |a Modern radiotherapy modalities allow irradiation of the tumor to high dose values and irradiation of organs at risk to low dose values at the same time. This paper studies geometrical radiation treatment plan parameters made in the Monaco system for Elekta Synergy linear accelerator. This study aims to select the optimal geometric characteristics of the plan with different target volume types. In the framework of the study, 12 dosimetric plans were created for each case. For the first case, anatomical data of a patient with prostate cancer was chosen in the mode of high-dose hypofractionated radiotherapy (5 fractions of 7.25 Gy). For the second case, the dosimetric treatment plans were prepared for the patient’s anatomical data with a complex shape of the target volume, base of tongue cancer, in the simultaneous integrated boost VMAT mode (25 fractions of 2.0 and 2.4 Gy) | ||
| 371 | 0 | |a AM_Agreement | |
| 461 | 1 | |0 (RuTPU)RU\TPU\network\4816 |t AIP Conference Proceedings | |
| 463 | 1 | |t Vol. 2820, iss. 1 : International Conference on Scientific Research and Innovation 2022 (ICSRI 2022) |o proceedings of the International Conference, 10–11 April 2022Cincinnati, USA |v 020009, 9 p. |d 2023 | |
| 510 | 1 | |a Влияние геометрических параметров на качество VMAT планов облучения при инверсном планировании объемно-модулированной лучевой терапии |z rus | |
| 610 | 1 | |a электронный ресурс | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a volumetric-modulated arc therapy | |
| 610 | 1 | |a quality assurance | |
| 610 | 1 | |a treatment planning system | |
| 610 | 1 | |a Monaco | |
| 610 | 1 | |a ArcCHECK | |
| 610 | 1 | |a 2D gamma analysis | |
| 610 | 1 | |a 3D gamma analysis | |
| 701 | 1 | |a Sukhikh |b E. S. |c specialist in the field of nuclear energy |c Associate Professor of Tomsk Polytechnic University, Candidate of Physical and Mathematical Sciences |f 1986- |g Evgeniya Sergeevna |3 (RuTPU)RU\TPU\pers\31215 |9 15411 | |
| 701 | 1 | |a Sukhikh |b L. G. |c physicist |c Professor of Tomsk Polytechnic University, Doctor of Sciences |f 1984- |g Leonid Grigorievich |3 (RuTPU)RU\TPU\pers\31554 |9 15714 | |
| 701 | 1 | |a Vertinsky |b A. V. |c specialist in the field of nuclear technologies |c Leading engineer of Tomsk Polytechnic University |f 1986- |g Andrey Vladimirovich |3 (RuTPU)RU\TPU\pers\47640 |9 23108 | |
| 701 | 1 | |a Stakhova |b O. M. |c specialist in the field of nuclear technologies |c engineer of Tomsk Polytechnic University |f 1998- |g Olga Mikhailovna |3 (RuTPU)RU\TPU\pers\47642 |9 23110 | |
| 801 | 2 | |a RU |b 63413507 |c 20230911 |g RCR | |
| 850 | |a 63413507 | ||
| 856 | 4 | |u https://doi.org/10.1063/5.0150411 |z https://doi.org/10.1063/5.0150411 | |
| 942 | |c CF | ||