Flexible photorecording fiber optical endoscope for the inner wall control of extensive cylindrical article; Modern Technique and Technologies. MTT 2002

Bibliografiske detaljer
Parent link:Modern Technique and Technologies. MTT 2002.— 2002.— P. 52-53
Hovedforfatter: Perelygin A. V.
Andre forfattere: Chigorko А. А. Anton Aleksandrovich
Summary:Currently, flexible fiber and optical endoscopes are attractive for the visual control of the collectors hollows, chemical apparatuses, different pipe lines. The problem associated with the movement of the endoscope flexible test portion inside of the article as well as impossibility of an exact objective positioning are the limitations for the endoscope application for the extensive cylindrical articles control with a narrow front neck of input. Moreover, in the articles controlled there are remaining liquid solutions and oil products that result in objective pollution and render the endoscope application under these conditions impossible. For the given problems solving there was developed photorecording endoscope with the system of axial movement and positioning flexible test portion inside of the extensive cylindrical articles.
Sprog:engelsk
Udgivet: 2002
Fag:
Format: Book Chapter
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=318685

MARC

LEADER 00000naa2a2200000 4500
001 318685
005 20260202115605.0
035 |a (RuTPU)RU\TPU\book\344186 
035 |a RU\TPU\book\325662 
090 |a 318685 
100 |a 20160503d2002 k||y0rusy50 ba 
101 0 |a eng 
102 |a RU 
200 1 |a Flexible photorecording fiber optical endoscope for the inner wall control of extensive cylindrical article  |f A. V. Perelygin, А. А. Chigorko 
330 |a Currently, flexible fiber and optical endoscopes are attractive for the visual control of the collectors hollows, chemical apparatuses, different pipe lines. The problem associated with the movement of the endoscope flexible test portion inside of the article as well as impossibility of an exact objective positioning are the limitations for the endoscope application for the extensive cylindrical articles control with a narrow front neck of input. Moreover, in the articles controlled there are remaining liquid solutions and oil products that result in objective pollution and render the endoscope application under these conditions impossible. For the given problems solving there was developed photorecording endoscope with the system of axial movement and positioning flexible test portion inside of the extensive cylindrical articles. 
463 0 |0 (RuTPU)RU\TPU\book\68530  |y 0-7803-7373-1  |t Modern Technique and Technologies. MTT 2002  |o proceedings of the 8th International Scienific and Practical Conference of Students. Post-graduates and Young Scientists, April 8 - April 12, 2002, Tomsk, Russia  |v P. 52-53  |d 2002 
610 1 |a труды учёных ТПУ 
700 1 |a Perelygin  |b A. V. 
701 1 |a Chigorko  |b А. А.  |c Specialist in the field of non-destructive testing  |c Research associate of Tomsk Polytechnic University  |f 1984-  |g Anton Aleksandrovich  |3 (RuTPU)RU\TPU\pers\36628 
801 1 |a RU  |b 63413507  |c 20130711 
801 2 |a RU  |b 63413507  |c 20160503  |g RCR 
942 |c BK