Comparison of X-ray sources on the basis of bremsstrahlung and parametric radiations; Bulletin of the Tomsk Polytechnic University; Vol. 311, № 2

Бібліографічні деталі
Parent link:Bulletin of the Tomsk Polytechnic University/ Tomsk Polytechnic University (TPU).— , 2006-2007
Vol. 311, № 2.— 2007.— [P. 53-57]
Автор: Gogolev A. S. Aleksey Sergeevich
Інші автори: Potylitsyn A. P. Alexander Petrovich
Резюме:Заглавие с титульного листа
Электронная версия печатной публикации
The comparative analysis of the X-ray tube and source on the basis of parametric X-ray radiation has been carried out. The parametric X-ray radiation intensity of source on the basis of compact linear accelerator with beam energy of 6 MeV and current of 100 μA is compared with intensity of ordinary X-ray tube. The performance of slow change of parametric X-ray line energy in a wide range from 6 to 130 keV with line width of about 300 eV may provide the good contrast of received image and decreases the radiation dose
Мова:Англійська
Опубліковано: 2007
Серія:Mathematics and mechanics.Physics
Предмети:
Онлайн доступ:http://www.lib.tpu.ru/fulltext/v/Bulletin_TPU/2007/v311eng/i2/15.pdf
Формат: Електронний ресурс Частина з книги
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=182603

MARC

LEADER 00000nla2a2200000 4500
001 182603
005 20240218125633.0
035 |a (RuTPU)RU\TPU\book\197949 
035 |a RU\TPU\book\197948 
090 |a 182603 
100 |a 20100623d2007 k y0rusy50 ca 
101 1 |a eng  |c rus 
102 |a RU 
135 |a drnn ---uucaa 
200 1 |a Comparison of X-ray sources on the basis of bremsstrahlung and parametric radiations  |f A. S. Gogolev, A. P. Potylitsin 
203 |a Text  |c electronic 
215 |a 1 файл (1.2 Мб) 
225 1 |a Mathematics and mechanics.Physics 
300 |a Заглавие с титульного листа 
300 |a Электронная версия печатной публикации 
320 |a [Bibliography: p. 57 (11 titles)] 
330 |a The comparative analysis of the X-ray tube and source on the basis of parametric X-ray radiation has been carried out. The parametric X-ray radiation intensity of source on the basis of compact linear accelerator with beam energy of 6 MeV and current of 100 μA is compared with intensity of ordinary X-ray tube. The performance of slow change of parametric X-ray line energy in a wide range from 6 to 130 keV with line width of about 300 eV may provide the good contrast of received image and decreases the radiation dose 
337 |a Adobe Reader 
461 1 |0 (RuTPU)RU\TPU\book\169973  |t Bulletin of the Tomsk Polytechnic University  |f Tomsk Polytechnic University (TPU)  |d 2006-2007 
463 1 |0 (RuTPU)RU\TPU\book\197892  |x 1684-8519  |t Vol. 311, № 2  |v [P. 53-57]  |d 2007  |p 153 p. 
610 1 |a sources 
610 1 |a X-ray radiation 
610 1 |a bremsstrahlung 
610 1 |a parametric radiations 
610 1 |a comparative analysis 
610 1 |a X-ray tubes 
610 1 |a linear accelerators 
610 1 |a energy 
610 1 |a current 
610 1 |a beams 
610 1 |a contrast 
610 1 |a images 
610 1 |a труды учёных ТПУ 
610 1 |a электронный ресурс 
675 |a 537.533.7  |v 3 
700 1 |a Gogolev  |b A. S.  |c physicist  |c associate professor of Tomsk Polytechnic University, Candidate of physical and mathematical sciences  |f 1983-  |g Aleksey Sergeevich  |3 (RuTPU)RU\TPU\pers\31537  |9 15698 
701 1 |a Potylitsyn  |b A. P.  |c Russian physicist  |c Professor of the TPU  |f 1945-  |g Alexander Petrovich  |3 (RuTPU)RU\TPU\pers\26306  |9 12068 
801 1 |a RU  |b 63413507  |c 20090623  |g PSBO 
801 2 |a RU  |b 63413507  |c 20151116  |g PSBO 
856 4 |u http://www.lib.tpu.ru/fulltext/v/Bulletin_TPU/2007/v311eng/i2/15.pdf 
942 |c CF