Comparison of X-ray sources on the basis of bremsstrahlung and parametric radiations; Bulletin of the Tomsk Polytechnic University; Vol. 311, № 2
| Parent link: | Bulletin of the Tomsk Polytechnic University/ Tomsk Polytechnic University (TPU).— , 2006-2007 Vol. 311, № 2.— 2007.— [P. 53-57] |
|---|---|
| Автор: | |
| Інші автори: | |
| Резюме: | Заглавие с титульного листа Электронная версия печатной публикации The comparative analysis of the X-ray tube and source on the basis of parametric X-ray radiation has been carried out. The parametric X-ray radiation intensity of source on the basis of compact linear accelerator with beam energy of 6 MeV and current of 100 μA is compared with intensity of ordinary X-ray tube. The performance of slow change of parametric X-ray line energy in a wide range from 6 to 130 keV with line width of about 300 eV may provide the good contrast of received image and decreases the radiation dose |
| Мова: | Англійська |
| Опубліковано: |
2007
|
| Серія: | Mathematics and mechanics.Physics |
| Предмети: | |
| Онлайн доступ: | http://www.lib.tpu.ru/fulltext/v/Bulletin_TPU/2007/v311eng/i2/15.pdf |
| Формат: | Електронний ресурс Частина з книги |
| KOHA link: | https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=182603 |
MARC
| LEADER | 00000nla2a2200000 4500 | ||
|---|---|---|---|
| 001 | 182603 | ||
| 005 | 20240218125633.0 | ||
| 035 | |a (RuTPU)RU\TPU\book\197949 | ||
| 035 | |a RU\TPU\book\197948 | ||
| 090 | |a 182603 | ||
| 100 | |a 20100623d2007 k y0rusy50 ca | ||
| 101 | 1 | |a eng |c rus | |
| 102 | |a RU | ||
| 135 | |a drnn ---uucaa | ||
| 200 | 1 | |a Comparison of X-ray sources on the basis of bremsstrahlung and parametric radiations |f A. S. Gogolev, A. P. Potylitsin | |
| 203 | |a Text |c electronic | ||
| 215 | |a 1 файл (1.2 Мб) | ||
| 225 | 1 | |a Mathematics and mechanics.Physics | |
| 300 | |a Заглавие с титульного листа | ||
| 300 | |a Электронная версия печатной публикации | ||
| 320 | |a [Bibliography: p. 57 (11 titles)] | ||
| 330 | |a The comparative analysis of the X-ray tube and source on the basis of parametric X-ray radiation has been carried out. The parametric X-ray radiation intensity of source on the basis of compact linear accelerator with beam energy of 6 MeV and current of 100 μA is compared with intensity of ordinary X-ray tube. The performance of slow change of parametric X-ray line energy in a wide range from 6 to 130 keV with line width of about 300 eV may provide the good contrast of received image and decreases the radiation dose | ||
| 337 | |a Adobe Reader | ||
| 461 | 1 | |0 (RuTPU)RU\TPU\book\169973 |t Bulletin of the Tomsk Polytechnic University |f Tomsk Polytechnic University (TPU) |d 2006-2007 | |
| 463 | 1 | |0 (RuTPU)RU\TPU\book\197892 |x 1684-8519 |t Vol. 311, № 2 |v [P. 53-57] |d 2007 |p 153 p. | |
| 610 | 1 | |a sources | |
| 610 | 1 | |a X-ray radiation | |
| 610 | 1 | |a bremsstrahlung | |
| 610 | 1 | |a parametric radiations | |
| 610 | 1 | |a comparative analysis | |
| 610 | 1 | |a X-ray tubes | |
| 610 | 1 | |a linear accelerators | |
| 610 | 1 | |a energy | |
| 610 | 1 | |a current | |
| 610 | 1 | |a beams | |
| 610 | 1 | |a contrast | |
| 610 | 1 | |a images | |
| 610 | 1 | |a труды учёных ТПУ | |
| 610 | 1 | |a электронный ресурс | |
| 675 | |a 537.533.7 |v 3 | ||
| 700 | 1 | |a Gogolev |b A. S. |c physicist |c associate professor of Tomsk Polytechnic University, Candidate of physical and mathematical sciences |f 1983- |g Aleksey Sergeevich |3 (RuTPU)RU\TPU\pers\31537 |9 15698 | |
| 701 | 1 | |a Potylitsyn |b A. P. |c Russian physicist |c Professor of the TPU |f 1945- |g Alexander Petrovich |3 (RuTPU)RU\TPU\pers\26306 |9 12068 | |
| 801 | 1 | |a RU |b 63413507 |c 20090623 |g PSBO | |
| 801 | 2 | |a RU |b 63413507 |c 20151116 |g PSBO | |
| 856 | 4 | |u http://www.lib.tpu.ru/fulltext/v/Bulletin_TPU/2007/v311eng/i2/15.pdf | |
| 942 | |c CF | ||