The study of the tree-inception phenomenon in LDPE; Korus 2004; V. 1

Bibliografische gegevens
Parent link:Korus 2004: The 8th Korea-Russia International Symposium on Science and Technology, June 26 - July 3, 2004, At Tomsk Politechnic University, Russia/ Novosibirsk State Technical University; Tomsk Polytechnic University.— , 2004-
V. 1.— 2004.— P. 210-213
Andere auteurs: Gefle O. S. Olga Semenovna, Lebedev S. M. Sergey Mikhailovich, Pokholkov Y. P. Yuri Petrovich, Cherkashina E. J., Golenko O. V., Lavrov V. Y., Kolesnikov A. A.
Samenvatting:The results of study of the tree-inception process in LDPE in the needle-plane configuration under 50 Hz AC voltage are represented in this paper. The tree-inception was studied in visible, UV, and IR spectra with simultaneous monitoring the PD-parameters. It was established that the tree-inception is accompanied by the radiation in visible and UV spectra and by the local temperature rise on the sample surface by a factor of 1.5 to 2 irrespective of the experimental conditions such as the applied voltage, the needle tip radius and interelectrode distance. It was found the direct correlation between the temperature-temporal parameters and PD-parameters of the tree-inception process. It was shown that a diagnostics of the tree inception by means of measurements of the local temperature rise on the dielectric surface and PD-parameters is possible
Taal:Engels
Gepubliceerd in: 2004
Onderwerpen:
Formaat: Hoofdstuk
KOHA link:https://koha.lib.tpu.ru/cgi-bin/koha/opac-detail.pl?biblionumber=173123

MARC

LEADER 00000naa2a2200000 4500
001 173123
005 20260424154419.0
035 |a (RuTPU)RU\TPU\book\187780 
090 |a 173123 
100 |a 20091219a2003 k y0engy50 ba 
101 0 |a eng 
102 |a RU 
200 1 |a The study of the tree-inception phenomenon in LDPE  |f O. S. Gefle [et al.] 
330 |a The results of study of the tree-inception process in LDPE in the needle-plane configuration under 50 Hz AC voltage are represented in this paper. The tree-inception was studied in visible, UV, and IR spectra with simultaneous monitoring the PD-parameters. It was established that the tree-inception is accompanied by the radiation in visible and UV spectra and by the local temperature rise on the sample surface by a factor of 1.5 to 2 irrespective of the experimental conditions such as the applied voltage, the needle tip radius and interelectrode distance. It was found the direct correlation between the temperature-temporal parameters and PD-parameters of the tree-inception process. It was shown that a diagnostics of the tree inception by means of measurements of the local temperature rise on the dielectric surface and PD-parameters is possible 
461 0 |0 (RuTPU)RU\TPU\book\73635  |t Korus 2004  |o The 8th Korea-Russia International Symposium on Science and Technology, June 26 - July 3, 2004, At Tomsk Politechnic University, Russia  |o proceedings  |f Novosibirsk State Technical University; Tomsk Polytechnic University  |d 2004- 
463 0 |0 (RuTPU)RU\TPU\book\73148  |t V. 1  |v P. 210-213  |d 2004 
610 1 |a труды учёных ТПУ 
701 1 |a Gefle  |b O. S.  |c physicist  |c Senior researcher of Tomsk Polytechnic University, Candidate of technical sciences  |f 1947-  |g Olga Semenovna  |3 (RuTPU)RU\TPU\pers\33671 
701 1 |a Lebedev  |b S. M.  |c physicist  |c Head of the laboratory of Tomsk Polytechnic University, Doctor of technical sciences  |f 1954-  |g Sergey Mikhailovich  |3 (RuTPU)RU\TPU\pers\34631  |9 17993 
701 1 |a Pokholkov  |b Y. P.  |c Russian physicist, electrical engineer, doctor of engineering  |c Rector of the TPU (1990 - 2008), professor  |f 1939-  |g Yuri Petrovich  |3 (RuTPU)RU\TPU\pers\24842 
701 1 |a Cherkashina  |b E. J. 
701 1 |a Golenko  |b O. V. 
701 1 |a Lavrov  |b V. Y. 
701 1 |a Kolesnikov  |b A. A. 
801 1 |a RU  |b 63413507  |c 20091219 
801 2 |a RU  |b 63413507  |c 20151126  |g RCR 
942 |c BK